Sunwind's LED Emergency Light always supply reliable lighting and clear directions to guide people during emergency time.
The EB18927269 LED Exit Sign Light is designed for commercial buildings, public facilities, and other environments where reliable exit signage and emergency lighting are required. Featuring a high-brightness LED light source, a 12W rated power consumption, and a built-in 1.2V/3.2Ah battery, this model combines clear sign illumination with emergency backup functionality.
Designed with an aluminum frame and flame-retardant PC components, the EB18927269 offers a practical solution for building owners, electrical contractors, emergency lighting distributors, and project procurement teams.
One of its key features is an automatic self-test function with monthly and yearly test cycles. Failure and charging indicators help users check the unit's status, while overcharge and over-discharge protection supports battery management. Optional sign designs, customized services, and universal plug options provide additional flexibility for different installation and project requirements.
For projects requiring an LED emergency exit sign with automatic testing, battery backup, and customizable signage, the EB18927269 is a model worth considering.
High-Brightness LED Source: Provides illuminated exit signage with reduced light depreciation over time.
12W Rated Power Consumption: Offers LED-based sign illumination for commercial and public-building applications.
Built-In Battery Backup: Uses a 1.2V/3.2Ah battery to support emergency operation.
Automatic Self-Test: Supports monthly and yearly self-test cycles to help assess emergency-lighting system status.
Charging and Failure Indicators: Visual indicators help users identify charging status and potential faults.
Battery Protection: Overcharge and over-discharge protection helps protect the battery during operation.
Aluminum and Flame-Retardant PC Construction: Combines an aluminum frame with flame-retardant polycarbonate components.
Flexible Plug Options: Optional universal plugs help accommodate different installation requirements.
Customizable Exit Signs: Optional sign designs and customization services are available for project-specific needs.
Low-Maintenance Design: Designed to reduce routine maintenance requirements; periodic inspection and functional testing are still necessary.
| Item | Specification |
|---|---|
| Product Name | LED Exit Sign Light |
| Model / Article Number | EB18927269 |
| Power Consumption | 12W |
| Light Source | LED |
| Surface Illuminance | 50–300 cd/m² |
| Battery Rating | 1.2V / 3.2Ah |
| Charging Time | Less than 24 hours |
| Standby / Emergency Duration | More than 2 hours |
| Input Voltage | AC 90–265V |
| Input Frequency | 50–60Hz |
| Frame Material | Aluminum |
| Other Housing Material | Flame-retardant PC |
| Automatic Self-Test | Monthly and yearly |
| Status Indicators | Failure indicator and charging indicator |
| Battery Protection | Overcharge and over-discharge protection |
| Plug Options | Universal plugs available as an option |
| Sign Options | Optional sign designs |
| Customization | Available upon request |
Technical note: The supplied specification lists a battery rating of 1.2V/3.2Ah and a standby time of more than 2 hours. Please confirm the battery configuration and the exact meaning of “standby time” with the manufacturer before publication or project approval.
The EB18927269 uses a high-brightness LED light source designed to maintain useful sign illumination while limiting light depreciation over time.
Its specified surface illuminance range is 50–300 cd/m². This measurement describes the luminance of the illuminated sign surface, rather than the illuminance falling on a floor or work surface.
For building operators and project buyers, LED technology offers a practical way to provide illuminated exit signage while managing energy consumption and ongoing operating requirements. Actual visibility depends on the sign design, viewing angle, installation position, ambient lighting, and the applicable local standards.
The EB18927269 features an automatic self-test function with monthly and yearly test cycles. This function is intended to help assess the unit's emergency-lighting operation and identify potential faults.
The failure indicator provides a visual reference when a fault is detected, while the charging indicator helps users check charging status.
Automatic testing can support routine maintenance planning, but it should not be treated as a replacement for inspections required by local regulations. Before installation, buyers should confirm the self-test sequence, test duration, fault indications, and whether test records or additional monitoring functions are supported.
This LED exit sign is specified with a 1.2V/3.2Ah battery and a charging time of less than 24 hours. The listed standby or emergency duration is more than 2 hours.
Overcharge and over-discharge protection helps protect the battery during charging and discharge cycles. These features support battery management and help reduce the risk of damage caused by unsuitable charging or excessive discharge.
For projects with mandatory emergency-lighting duration requirements, confirm the complete battery configuration, rated emergency duration, charging method, and battery replacement procedure with the manufacturer. The product's stated duration should be checked against the requirements of the installation market.
The EB18927269 combines an aluminum frame with flame-retardant polycarbonate (PC) components. This material combination is intended for practical use in commercial and public-building environments.
The aluminum frame provides structural support, while flame-retardant PC components form part of the product construction. Specific fire-test classifications, impact resistance, ingress protection, and environmental ratings should be verified through the manufacturer's technical documents rather than assumed from the material description alone.
Different buildings and markets may require different mounting arrangements, plug configurations, and exit sign layouts. The EB18927269 offers optional universal plugs, optional sign designs, and customization services to help meet project requirements.
When requesting a quotation, buyers should provide:
Required exit sign wording, symbols, and arrow direction
Preferred plug or electrical connection arrangement
Installation type and mounting requirements
Order quantity and delivery destination
Applicable market standards and certification requirements
Available configurations, customization limits, minimum order quantities, and lead times should be confirmed before placing an order.
The EB18927269 LED Exit Sign Light may be considered for applications such as:
Commercial offices and business premises
Retail stores and shopping facilities
Hotels and hospitality buildings
Schools and educational facilities
Public buildings and shared facilities
Corridors, entrances, and designated exit routes
Commercial construction and renovation projects
The appropriate product configuration and installation location must be selected according to the building design and the applicable emergency-lighting and exit-signage regulations.
For dependable operation, install and maintain the LED exit sign according to the manufacturer's instructions and the applicable local requirements.
Recommended considerations include:
Check the power supply: Verify that the installation supply falls within AC 90–265V, 50–60Hz.
Confirm the installation configuration: Check the selected plug, mounting arrangement, and sign orientation before installation.
Verify charging status: Use the charging indicator to help confirm the charging condition.
Review self-test results: Check monthly and yearly self-test operation and respond to any fault indication according to the product manual.
Inspect the battery: Confirm that the battery provides the required emergency duration and replace it when necessary.
Keep the sign visible: Avoid obstructions that could prevent occupants from seeing the exit indication.
Maintain inspection records: Follow the testing and record-keeping requirements applicable to the installation location.
The product's automatic self-test function can assist with maintenance, but it does not eliminate the need for any legally required manual checks or professional inspections.
The model number is EB18927269.
The specified power consumption is 12W.
The unit is specified for AC 90–265V at 50–60Hz.
The supplied specification lists a battery rating of 1.2V/3.2Ah. Buyers should confirm the battery configuration with the manufacturer before finalizing project specifications.
The specified charging time is less than 24 hours.
The supplied specification states a standby time of more than 2 hours. Confirm the exact rated emergency operating duration and test conditions with the manufacturer.
Yes. The product specification lists automatic monthly and yearly self-tests. The exact test sequence and fault-detection scope should be confirmed in the product manual.
The unit includes a failure indicator and a charging indicator to help users check its operating and charging status.
The product uses an aluminum frame and flame-retardant PC components.
Yes. Optional sign designs and customization services are available. Contact the supplier to confirm the available symbols, wording, arrow directions, and order requirements.
Universal plugs are available as an option. Confirm the plug type and compatibility with the destination market before ordering.
Certification details were not included in the supplied specifications. Request the applicable certificates and test reports from the manufacturer and verify that they meet the requirements of your target market.
Looking for an LED emergency exit sign with automatic self-testing, battery backup, and customizable sign options?
Contact our team for pricing, technical documentation, available configurations, and customization details for the EB18927269 LED Exit Sign Light.
Contact: Johnson
Phone: 13632968671
E-mail: sunwindled@foxmail.com