LED Exit Sign(EB990)

DALI LED Exit Sign(EB990)

LED Exit Sign EB990 – LiFePO4 Battery Backup and Flexible Installation

Reliable LED Emergency Exit Sign for Commercial Buildings

The EB990 LED Exit Sign is designed to provide clear exit identification and emergency backup illumination in commercial and institutional buildings. Featuring a low-power LED light source, a rechargeable lithium iron phosphate (LiFePO4) battery, and a specified viewing distance of 24 metres, this emergency exit sign is a practical option for projects requiring dependable exit signage.

With a rated power consumption of just 4W, the EB990 combines energy-conscious operation with a compact housing measuring 360 × 223 × 80 mm. Its specified emergency standby time exceeds 3 hours, while the charging time is less than 16 hours under the manufacturer's stated conditions.

The EB990 supports wall or ceiling surface mounting and suspended installation, allowing contractors to adapt the sign to different building layouts. Changeable diffusers provide additional flexibility for signage configuration, while manual testing and half-yearly testing functionality support routine inspection and maintenance.

The unit features a three-colour indicator system in green, red, and yellow to help communicate equipment status. Its low-voltage cut-off protection is designed to help prevent excessive battery discharge.

Specified with a PC body, PE diffuser, and a milky PC diffuser holder designed to transmit light, the EB990 is suitable for evaluation in offices, commercial premises, educational facilities, hospitality environments, and other buildings where compliant emergency exit signage is required.

Key Features of the EB990 LED Exit Sign

  • 4W power consumption: Low-power LED operation for everyday exit signage.

  • LED light source: Provides illuminated exit sign visibility.

  • LiFePO4 rechargeable battery: Lithium iron phosphate battery technology for emergency backup.

  • More than 3 hours of standby time: Specified emergency operating duration.

  • 24-metre viewing distance: Manufacturer-rated viewing distance, subject to installation and applicable requirements.

  • AC110V / AC220V power supply: Supports the specified voltage options at 50Hz or 60Hz.

  • Manual and half-yearly testing: Supports routine emergency sign inspection.

  • Three-colour status indicator: Green, red, and yellow indicators.

  • Low-voltage cut-off protection: Helps prevent battery over-discharge.

  • Changeable diffusers: Supports configuration flexibility.

  • Multiple mounting options: Wall, ceiling surface, or suspended mounting.

  • Easy installation and maintenance: Designed for convenient installation and routine servicing.

  • Compact enclosure: Dimensions of 360 × 223 × 80 mm.

  • Three-year warranty: Product warranty of 3 years, with a separate 1-year battery warranty.

  • Compliance specification: Manufacturer lists SAA / AS 2293.3-2018; verify the applicable certification documentation for the exact model.

Product Specifications

ParameterSpecification
Product NameLED Exit Sign
Model NumberEB990
Power Consumption4W
Power SupplyAC 110V / AC 220V
Frequency50Hz / 60Hz
Light SourceLED
Viewing Distance24 metres
Standby Time>3 hours
Charging Time<16 hours
Auto Testing / TestingManual testing and half-yearly testing
Status IndicatorsGreen / Red / Yellow
Battery TypeLiFePO4
Battery Capacity3.2V / 2200mAh
Battery ProtectionLow-voltage cut-off to help prevent over-discharge
Body MaterialPC
Diffuser MaterialPE
Diffuser HolderMilky PC with light transmission
MountingWall or ceiling surface; suspended
Cable EntryØ21.00 mm hole
Dimensions360 × 223 × 80 mm
Weight0.8 kg
Listed ComplianceSAA / AS 2293.3-2018
Warranty3 years; battery warranty 1 year
Design CharacteristicsLow power consumption, long-life LED source, changeable diffuser

Note: Product performance, viewing distance, testing intervals, and compliance should be verified against the manufacturer's current datasheet and relevant certification documents before the product is specified for a regulated project.

LiFePO4 Battery Backup for Emergency Operation

Emergency exit signs must remain visible when normal power is interrupted. The EB990 incorporates a rechargeable LiFePO4 battery rated at 3.2V and 2200mAh, with a specified standby duration of more than 3 hours.

Lithium iron phosphate battery technology is commonly selected for rechargeable equipment because of its battery chemistry characteristics. Actual service life and emergency performance depend on charging conditions, ambient temperature, battery age, maintenance, and the design of the emergency circuit.

The EB990 has a specified charging time of less than 16 hours. For reliable emergency operation, the battery should be charged, tested, and maintained according to the manufacturer's instructions and applicable local regulations.

Its low-voltage cut-off function helps protect the battery against excessive discharge. This protection is intended to support battery management but does not remove the need for periodic inspection or eventual battery replacement.

Manual and Half-Yearly Testing

Emergency exit signs require routine inspection to confirm that the sign and its backup power system remain operational.

The EB990 specifications identify manual testing and half-yearly testing. These functions can support building maintenance procedures and help facility managers organise routine checks.

Testing should follow the manufacturer's instructions and the requirements applicable to the building. Confirm the exact testing procedure and whether the unit provides any automatic self-test function before selecting it for a project that requires automatic testing.

The three-colour indicator system—green, red, and yellow—provides status indication. Refer to the manufacturer's documentation for the meaning of each colour and the corresponding operating or fault conditions.

Flexible Mounting for Different Building Layouts

The EB990 supports wall-mounted, ceiling-mounted, and suspended installation. This flexibility allows project designers to consider the sign location, viewing direction, ceiling height, and building layout when selecting the installation method.

Its enclosure measures 360 × 223 × 80 mm and weighs approximately 0.8 kg. A specified Ø21 mm cable-entry hole supports the intended electrical connection arrangement.

The PC body and PE diffuser are selected for the product's lighting and enclosure design. Before installation, check the mounting accessories, cable-entry requirements, ceiling structure, visibility, and local electrical safety rules.

Correct positioning is essential: exit signage should be clearly visible along designated escape routes and at relevant decision points in accordance with the applicable building and fire safety requirements.

Changeable Diffusers for Signage Flexibility

The EB990 features changeable diffusers, providing flexibility for signage configuration and maintenance. The specified diffuser is made from PE, while the diffuser holder is described as milky PC with light transmission.

When choosing an exit sign, confirm the available legend, arrow direction, viewing orientation, and any required pictogram or language options. Signage must accurately indicate the approved escape route and comply with the regulations applicable to the installation location.

Do not assume that every legend, arrow, or double-sided configuration is included as standard. Request confirmation of the supplied accessories and available variants before ordering.

Typical Applications

The EB990 LED Exit Sign may be considered for buildings where illuminated exit identification and emergency backup are required, subject to the relevant certification and installation conditions.

  • Office buildings: Exit identification along corridors and designated escape routes.

  • Commercial premises: Emergency exit signage for retail and business facilities.

  • Hotels and hospitality buildings: Exit identification in suitable circulation areas.

  • Educational facilities: Signage for approved escape routes and building exits.

  • Healthcare and institutional buildings: Exit signage where the selected model meets project requirements.

  • Industrial and warehouse buildings: Emergency exit identification in compatible indoor environments.

  • Public buildings: Exit signage for buildings subject to applicable emergency lighting and evacuation regulations.

The suitability of the EB990 for any specific project depends on the required viewing distance, legend, mounting arrangement, emergency duration, and relevant product approvals.

Compliance with SAA and AS 2293.3-2018

The supplied product specifications list SAA / AS 2293.3-2018 as the applicable compliance reference.

For Australian emergency exit sign projects, buyers should verify the product's certification status, applicable standard edition, covered model number, and supporting documentation before procurement. A reference in a product datasheet should not be treated as a substitute for checking the relevant certificate or declaration.

Project designers and electrical contractors should also confirm that the selected sign, installation method, viewing distance, and emergency operating duration satisfy the requirements of the building and its applicable regulations.

Why Choose the EB990 LED Exit Sign?

When selecting an LED emergency exit sign, procurement teams should consider visibility, standby duration, battery type, charging time, installation flexibility, testing arrangements, and compliance documentation.

The EB990 combines a 4W LED light source with a 3.2V, 2200mAh LiFePO4 battery, more than 3 hours of specified standby time, a 24-metre viewing distance, and wall, ceiling, or suspended mounting options.

Its changeable diffuser, tri-colour status indicators, and low-voltage cut-off protection provide additional features for emergency signage projects. The listed three-year product warranty and one-year battery warranty also give buyers a basis for evaluating lifecycle support.

For distributors, electrical contractors, project consultants, and facility managers, the next step is to confirm the required legend, mounting accessories, certification documents, and testing procedure for the intended installation.

Frequently Asked Questions

1. What is the model number of this LED exit sign?

The model number is EB990.

2. What is the power consumption of the EB990?

The specified power consumption is 4W.

3. How long can the EB990 operate during a power failure?

The specified emergency standby time is more than 3 hours. Actual performance depends on battery condition, operating conditions, and the approved product configuration.

4. What battery does the EB990 use?

The product specifications list a lithium iron phosphate (LiFePO4) battery rated at 3.2V and 2200mAh.

5. How long does the battery take to charge?

The specified charging time is less than 16 hours.

6. What is the viewing distance of the EB990 exit sign?

The listed viewing distance is 24 metres. Confirm the permitted viewing distance and installation requirements against the applicable standards and project documentation.

7. Can the EB990 be mounted on a wall or ceiling?

Yes. The listed mounting options include wall or ceiling surface mounting and suspended installation.

8. Does the EB990 have automatic testing?

The supplied specifications identify manual testing and half-yearly testing. Automatic self-testing is not clearly confirmed in the provided technical data, so buyers should verify this feature if it is a project requirement.

9. What do the green, red, and yellow indicators mean?

The EB990 has green, red, and yellow status indicators. The specific meaning of each colour should be confirmed in the manufacturer's operating instructions.

10. What standards or approvals are listed?

The supplied specifications list SAA / AS 2293.3-2018. Request the applicable certificate and verify the covered model and compliance status before installation.

11. What is the warranty period?

The listed warranty is three years for the product and one year for the battery. Confirm the written warranty terms, exclusions, and battery replacement conditions with the supplier.

12. Can the diffuser be changed?

Yes. The specifications identify changeable diffusers. Confirm available legends, arrow directions, mounting accessories, and replacement part options before ordering.

Request a Quote for the EB990 LED Exit Sign

Looking for an LED exit sign for a commercial or institutional project? Contact our team for pricing, technical documentation, available legends, mounting options, certification information, and warranty details.

Product Model: EB990
Power Consumption: 4W
Battery: LiFePO4, 3.2V / 2200mAh
Standby Time: >3 hours
Charging Time: <16 hours
Viewing Distance: 24 metres
Mounting Options: Wall, ceiling surface, or suspended
Listed Compliance: SAA / AS 2293.3-2018
Warranty: 3 years for the product; 1 year for the battery

Contact us to discuss your emergency exit signage requirements and request a quotation for the EB990.


INQUIRY

Scan the qr codeclose
the qr code

AI Assistant

Type your question above